9,999-Count Display Span
100 mV to 650 V Ranges
2 ╡A to 1 A Ranges
Special Scaling for 5 A Current Transformer
0.1 mV/Count Analog Output
Front-Panel Accessible Span Adjustment
Bright, 0.56" (14.2 mm) LED Display
Display Hold and Test
120/240 Vac, 9-32 Vdc Power
Screw-Terminal Barrier Strip
1/8 DIN Case |
Q2000-C
/ Q2000-F /
Q2000-D / Q2000-G
Q8000-C / Q8000-D
Q9000-C / Q9000-F
/ Q9000-D /
Q9000-G
|
1/8
DIN (1A) Case
|
Connections
Diagram
|
|
OPTIONS
Analog Output for User-Selected Span
Single-Setpoint 10 A Relay Control
Dual-Setpoint 10 A Relay Control
Parallel BCD Output, Isolated
The QUANTA«
AC AVG voltmeter and ammeter use a precision op-amp rectifier circuit
to provide an economical AC-average meter, which is calibrated to display
the true-RMS value of sinusoidal signals. The QUANTA AC RMS voltmeter
and ammeter use an integrated circuit that computes the true-root-mean-square
value of complex waveforms. Screw-terminals are provided for AC or DC
coupling. AC coupling allows the measurement of the AC component or ripple
from a signal with both AC and DC components. DC coupling allows the measurement
of true-RMS, including both DC and AC components.
The signal conditioner provides six current ranges, as determined by an
internal shunt resistor. In addition, there is a special 5 A range, which
allows direct connection to a current transformer (CT) with 5 A secondary,
without need for a stepdown transformer. Proper scaling is obtained for
primary currents of 10, 100 and 1000 A.
SPECIFICATIONS
ANALOG
INPUT, Q2000C & Q2000F
Range
|
|
199.9 mV
|
1.999 V
|
Resolution
|
|
100 µV
|
1 mV
|
Maximum
input
|
|
50 Vp
|
100 Vp
|
Input resistance
|
|
1.1 Mohm
|
1.1 Mohm
|
Range
|
19.99 V
|
199.9 V
|
650 V
|
Resolution
|
10 mV
|
100 mV
|
1 V
|
Maximum
input
|
250 Vp
|
500 Vp
|
920 Vp
|
Input resistance
|
1.0 Mohm
|
1.0 Mohm
|
10 Mohm
|
ANALOG INPUT, Q2000D & Q2000G
Range
|
19.99 µA
|
199.9 µA
|
1.999 mA
|
Resolution
|
10 nA
|
100 nA
|
1 µA
|
Maximum
input
|
3 mA
|
10 mA
|
30 mA
|
Input resistance
|
10 kohm
|
1 kohm
|
100ohm
|
Range
|
19.99 mA
|
199.9 mA
|
1.999 A
|
Resolution
|
10 µA
|
100 µA
|
1 mA
|
Maximum
input
|
100 mA
|
500 mA
|
2.2 A
|
Input resistance
|
10 ohm
|
1 ohm
|
0.1 ohm
|
Range
|
19.99 A
|
199.9 A
|
1999 A
|
Resolution
|
10 mA
|
100 mA
|
1 A
|
Maximum
input
|
5 A CT
|
5 A CT
|
5 A CT
|
Input resistance
|
0.01ohm
|
0.01ohm
|
0.01ohm
|
ANALOG INPUT, Q9000C & Q9000F
Range
|
99.99 mV
|
999.9 mV
|
Resolution
|
10 ╡V
|
100 ╡V
|
Maximum
Input
|
50 Vp
|
100 Vp
|
Input Resistance
|
1.1 Mohm
|
1.1 Mohm
|
Range
|
9.999 V
|
99.99 V
|
650.V
|
Resolution
|
1 mV
|
10 mV
|
100 mV
|
Maximum
Input
|
250 Vp
|
500 Vp
|
920 Vp
|
Input Resistance
|
1.0 Mohm
|
1.0 Mohm
|
10 Mohm
|
ANALOG INPUT, Q9000D & Q9000G
Range
|
9.999 ╡A
|
99.99 ╡A
|
999.9 ╡A
|
Resolution
|
1 nA
|
10 nA
|
100 nA
|
Maximum
Input
|
3 mA
|
10 mA
|
30 mA
|
Input Resistance
|
10 kohm
|
1 kohm
|
100 ohm
|
Range
|
9.999 A
|
99.99 A
|
999.9 A
|
Resolution
|
1 mA
|
10 mA
|
100 mA
|
Maximum
Input
|
5 A CT
|
5 A CT
|
5 A CT
|
Input Resistance
|
0.01 ohm
|
0.01 ohm
|
0.01 ohm
|
ACCURACY at 25░C (AC)
Maximum Error: ▒0.1% of reading ▒10 counts
Span tempco: ▒0.01% of reading/░C (AC)
Step response: 1 s to 99.9% of span
Frequency range for rated accuracy: 147 to 1000 Hz
Warmup to rated accuracy: Less than 30 min.
ACCURACY at 25░C (RMS) (1% to 100% of full
scale)
Maximum error, AC coupling: ▒0.1% of reading ▒10 cts, 47 Hz to 5 kHz
Maximum error, DC coupling: ▒0.1% of reading ▒10 cts, 9 Hz to 5
kH
Span tempco: ▒0.03% of reading/░C (typ)
Zero tempco: 0.15 mV/░C (typ)
Step response: 1 sec to 99.9% of span
Warmup to rated accuracy: Less than 30 min.
CONVERSION
Technique: Dual-slope, average-value
Signal integration period: 100 ms
Read rate: 2.5/sz
Range Code |
Input Range |
Range
Code |
True
RMS |
Q2000
/ Q3000 |
Q9000
/ Q8000 |
CVR2
|
FVR2
|
199.99 mV
|
99.99 mV
|
CVR3
|
FVR3
|
1.999 V
|
999.9 mV
|
CVR4
|
FVR4
|
19.99 V
|
9.999 V
|
CVR5
|
FVR5
|
199.9 V
|
99.99 V
|
CVR6
|
FVR6
|
650 V
|
650.0 V
|
DCR1
|
GCR1
|
19.99 ╡A
|
9.999 ╡A
|
DCR2
|
GCR2
|
199.9 ╡A
|
99.99 ╡A
|
DCR3
|
GCR3
|
1.999 mA
|
999.9 ╡A
|
DCR4
|
GCR4
|
19.99 mA
|
9.999 mA
|
DCR5
|
GCR5
|
199.99 mA
|
99.99 mA
|
DCR6
|
GCR6
|
1.999 A
|
999.9 mA
|
DCR7
|
GCR7
|
5 A CT
|
5
A CT
|
To Order ( * Complete Model No.) Prices Shown
in U.S. Dollars
Q(
* ) |
(
* ) |
(
* ) |
(
* ) |
POWER AND
CASE
|
Price
|
2
|
|
|
|
3
1/2 digit standard case |
$210
|
3
|
|
|
|
3
1/2 digit INFINITY® case |
$240
|
8
|
|
|
|
4
digit INFINITY® case |
$250
|
9
|
|
|
|
4
digit standard case |
$280
|
|
|
|
|
POWER |
|
|
0
|
|
|
120
Vac (49/440 Hz) |
N/C
|
|
2
|
|
|
240
Vac (49/440 Hz) |
N/C
|
|
4
|
|
|
9-32
Vdc (isolated) |
$145
|
|
|
|
|
ANALOG
OUTPUT |
|
|
|
0
|
|
▒1
or ▒2 V non-isolated
|
N/C
|
|
|
2
|
|
0-10
Vdc non-isolated |
$70
|
|
|
4
|
|
Non-Isolated
4-20 mA |
$70
|
|
|
6
|
|
Isolated
4-20 mA |
$135
|
|
|
|
|
CONTROL
OUTPUTS |
|
|
|
|
0
|
None
|
N/C
|
|
|
|
1
|
Dual-setpoint 10 A from ôCö relay |
$165
|
|
|
|
4
|
Isolated BCD (5 V Logic) |
$155
|
|
|
|
5
|
Single-setpoint 10 A from ôCö relay |
$125
|
|
|
|
|
CONTROL
OUTPUTS |
|
|
|
|
*
|
AC
AVG ôSelect Range Codeö |
$65
|
|
|
|
*
|
TRUE
RMS ôSelect Range Codeö |
$100
|
Splash
Proof Lens Cover
Model No.
|
Description
|
Price
|
SPC18
|
IP65/NEMA4
$30 with spring clamp |
$30
|
SPC4
|
IP65/NEMA4
30 with screw clamp |
$30
|
|